Part Number Hot Search : 
FE0803 YAAMUA A1010 4303F P0721SAL 223985 P0721SAL FDB5800
Product Description
Full Text Search
 

To Download LPS62 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  rev. 05.27.08 lps60 series 1 of 3 embedded power for business-critical continuity lps60 series 60 watts special features ? universal input ? 3" x 5" footprint ?remote sense ? built in emi filter ? low output ripple ? adjustable output voltage ? overload protection ? 110 khz switching frequency ? lpx60 enclosure kit available total power: 60 - 80 watts input voltage: 85 - 264 vac 120 - 300vdc # of outputs: single electrical specifications safety input input ra nge: 85 - 264 vac (wide range) 120 - 300 vdc frequency: 47-440 hz inrush current: <18a peak @ 115 vac, <36 a peak @230 vac, cold start @ 25 c input current: 1.5 a max. (rms) @ 115 vac efficiency: 70% typical at full load emi filter: fcc class b conducted; cispr22 class b conducted; en55022 class b conducted; vde0878pt3 class b conducted safety ground leakage current: <0.5 ma @ 50/60 hz; 264 vac input output maximum power: 60 w for convection; 80 w with 30 cfm forced air adjustment range -5, +10% minimum hold-up time 20 ms @ 60 w load, 115 vac nominal line overload protection short circuit protection on all outputs. case overload protected @ 110-145% above peak rating overvoltage protection 5 v output; 5.7 - 6.7 vdc. other outputs 10% to 25% above nominal output remote sense compensates for 0.5 v lead drop min. will operate without remote sense connected. reverse connection protected. vde 0805/en60950 (iec950) 11774-3336-1255 (lc #86665) ul ul1950 e132002 csa csa 22.2-234 level 3 lr53982c nemko en 60950/emko-tue p95100123 (74-sec) 203 cb certificate and report 1521, 1522, 1523, 1524 ce mark (lvd)
mechanical drawing 3.00" (76.2) 2.55" (64.8) 0.22" (5.6) 0.22" (5.6) 4.56" (115.8) 5.00" (127) 1.69" (42.9) 0.12" (3) sk 1 sk 2 1 2 3 4 5 6 0.15" (4) dia (4 places) gnd 1 3 n l m1 m2 remote sense connector _ + sk201 voltage adj. pot rev. 05.27.08 lps60 series 2 of 3 operating temperature: 0 to 50 c ambient derate each output as 2.5% per degree from 50 to 70 c, -20 c startup storage temperature: -40c to +85 c electromagnetic susceptibility: designed to meet iec801, -2, -3, -4, -5, -6, level 3 humidity: operating; non-condensing 5% to 95% rh vibration: three orthogonal axes, sweep at 1 cot/min, 5 min. dwell at four major resonances 0.75 g peak 5 hz to 500 hz, operational temperature coefficient 0.04% per c mtbf demonstrated >550,000 hours at full load and 25 c ambient conditions environmental specifications power derating curve output power (watts) 0c 20w 40w 60w 80w 10c 20c 30c 40c 50c 60c 70c ta C ambient temperature C c 0w natural convection cooling 40w 30w 30 cfm forced air cooling
rev. 05.27.08 lps60 series 3 of 3 embedded power for business-critical continuity ordering information model number output voltage minimum load maximum load with convection cooling maximum load with 30cfm forced air peak load 1 regulation 2 ripple p/p (pard) 3 lps61 3.3 v 2 a 12 a 16 a 18 a 2% 33 mv LPS62 5 v 0 a 12 a 16 a 18 a 2% 50 mv lps63 12 v 0 a 5 a 6.7 a 7.5 a 2% 120 mv lps64 15 v 0 a 4 a 5.3 a 6 a 2% 150 mv lps65 24 v 0 a 2.5 a 3.3 a 3.8 a 2% 240 mv lps68 48 v 0 a 1.3 a 1.7 a 1.9 a 2% 480 mv 1. peak current lasting <30 seconds with a maximum 10% duty cycle. 2 . at 25 c including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3 . peak-to-peak with 20 mhz bandwidth and 10 f (tantalum capacitor) in parallel with a 0.1 f capacitor at rated line voltage and load ranges. pin assignments connector lps61 LPS62 lps63 lps64 lps65 lps68 sk1-1 neutral neutral neutral neutral neutral neutral sk1-3 line line line line line line sk2-1 3.3 v 5 v +12 v +15 v +24 v 48 v sk2- 2 3.3 v 5 v +12 v +15 v +24 v 48 v sk2- 3 3.3 v 5 v +12 v +15 v +24 v 48 v sk2-4 common common common common common common sk2-5 common common common common common common sk2-6 common common common common common common sk201-1 +sense +sense +sense +sense +sense +sense sk201-2 -sense -sense -sense -sense -sense -sense mating connectors ac input: molex 09-50-8031 (usa) not required for (-t) option 09-91-0300 (uk) pins: 08-58-0111 dc outputs: molex 09-50-8061 (usa) not required for (-t) option 09-91-0600 (uk) pins: 08-58-0113 remote sense: molex 22-01-2025 pins: 08-52-0113 astec connector kit #70-841-006, includes all of the above 1. specifications subject to change without notice. 2. all dimensions in inches (mm), tolerance is 0.02" (0.5mm) 3. mounting holes m1 and m2 should be grounded for emi purposes. 4. mounting hole m1 is safety ground connection. 5. specifications are for convection rating at factory settings at 115 vac input, 25c unless otherwise stated. 6. warranty: 2 year 7. weight: 0.75lbs/0.34kg americas 5810 van allen way carlsbad, ca 92008 usa telephone: +1 (760) 930 4600 facsimile: +1 (760) 930 0698 europe (uk) waterfront business park merry hill, dudley west midlands, dy5 1lx united kingdom telephone: +44 (0) 1384 842 211 facsimile: +44 (0) 1384 843 355 asia (hk) 14/f, lu plaza 2 wing yip street kwun tong, kowloon hong kong telephone: +852 2176 3333 facsimile: +852 2176 3888 for global contact, visit: www.powerconversion.com techsupport.embeddedpower @emerson.com while every precaution has been taken to ensure accuracy and completeness in this literature, emerson network power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. emerson network power and the emerson network power logo are trademarks and service marks of emerson electric co. ?2008 emerson electric co. emersonnetworkpower. com embedded computing embedded power monitoring outside plant power switching & controls precision cooling racks & integrated cabinets services surge protection emerson network power. the global leader in enabling business-critical continuity. ac power connectivity dc power


▲Up To Search▲   

 
Price & Availability of LPS62

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X